مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

341
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

129
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

ASSESSMENT OF PATIENT DOSE FROM CT EXAMINATIONS IN KHORASAN, IRAN

Pages

  233-238

Keywords

DLP 
CT 

Abstract

 Introduction: Computed Tomography scans are a very important tool for diagnosis and assessment of response to treatment in the practice of medicine. Ionizing radiation in medical imaging is undoubtedly one of the most powerful diagnostic tools in medicine. Yet, as with all medical interventions, there are potential risks in addition to the clear potential benefits.Materials and Methods: Two reference dose quantities have been defined in order to promote the use of good technique in CT. These are weighted CT dose index (CTDIw) in (mGy) for a single slice in serial scanning or per rotation in helical scanning, and dose–length product (DLP) per complete examination (mGy.cm), All measurements were performed using a pencil shaped IONIZATION CHAMBER introduced into polymethyl methacrylate cylindrical brain and body phantoms. This survey was performed on 7 CT scanners in Khorasan Province-Iran.Results: DLP for brain, chest, abdomen and pelvic examinations had a range of 255 - 1026, 76-1277, 48-737, 69-854 mGy.cm, respectively.Conclusion: The results obtained in this study show that the DLP values obtained in this province are lower than European Commission reference dose levels (EC RDL), in other words performance of all the scanners were satisfactory.

Multimedia

  • No record.
  • Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    BAHREYNI TOOSSI, MOHAMMAD TAGHI, & BAHRAMI, MOHAMMAD. (2012). ASSESSMENT OF PATIENT DOSE FROM CT EXAMINATIONS IN KHORASAN, IRAN. IRANIAN JOURNAL OF MEDICAL PHYSICS, 9(4), 233-238. SID. https://sid.ir/paper/607210/en

    Vancouver: Copy

    BAHREYNI TOOSSI MOHAMMAD TAGHI, BAHRAMI MOHAMMAD. ASSESSMENT OF PATIENT DOSE FROM CT EXAMINATIONS IN KHORASAN, IRAN. IRANIAN JOURNAL OF MEDICAL PHYSICS[Internet]. 2012;9(4):233-238. Available from: https://sid.ir/paper/607210/en

    IEEE: Copy

    MOHAMMAD TAGHI BAHREYNI TOOSSI, and MOHAMMAD BAHRAMI, “ASSESSMENT OF PATIENT DOSE FROM CT EXAMINATIONS IN KHORASAN, IRAN,” IRANIAN JOURNAL OF MEDICAL PHYSICS, vol. 9, no. 4, pp. 233–238, 2012, [Online]. Available: https://sid.ir/paper/607210/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button