مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

37
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

71
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Gamma analysis of patient specific quality assurance by hybrid acceptance criterion method

Pages

  505-512

Abstract

 Background: gamma analysis is an effective tool used to verify treatment plan accuracy with regard to patient specific quality assurance. In this method, accuracy is validated through the major parameters presented in the acceptance criterion (AC). The Hybrid AC (HAC) method has been proposed and validated via the Traditional AC (TAC) method of comparison. Materials and Methods: The performance of the HAC method was investigated through one-dimensional (1D) relative dose profile and clinical planar dose distribution. By employing the HAC method, Gamma values were observed at different regions of the profile as well as at the different treatment sites of clinical planar dose distribution. Both results were compared by employing the TAC method, but only planar dose distribution was analyzed by 95% confidence interval of statistics. Results: The results of the HAC method indicate higher Gamma values at the penumbra of the dose profile when compared with the results of the TAC method. In low dose and high dose areas, both methods produced comparable results. In terms of planar dose distribution, the proposed method demonstrated a higher degree of sensitivity than the TAC method by indicating low values for the Gamma passing rate at all treatment sites. Conclusion: The HAC method could effectively increase the sensitivity of the tool at a high dose gradient of planar dose distribution, whereas it had no impact on the area of the low dose gradient. Therefore, this method could be an alternative option for evaluation of treatment planning accuracy in clinical practice.

Multimedia

  • No record.
  • Cites

  • No record.
  • References

    Cite

    APA: Copy

    Watcharawipha, A., & CHITAPANARUX, I.. (2023). Gamma analysis of patient specific quality assurance by hybrid acceptance criterion method. INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 21(3), 505-512. SID. https://sid.ir/paper/1078388/en

    Vancouver: Copy

    Watcharawipha A., CHITAPANARUX I.. Gamma analysis of patient specific quality assurance by hybrid acceptance criterion method. INTERNATIONAL JOURNAL OF RADIATION RESEARCH[Internet]. 2023;21(3):505-512. Available from: https://sid.ir/paper/1078388/en

    IEEE: Copy

    A. Watcharawipha, and I. CHITAPANARUX, “Gamma analysis of patient specific quality assurance by hybrid acceptance criterion method,” INTERNATIONAL JOURNAL OF RADIATION RESEARCH, vol. 21, no. 3, pp. 505–512, 2023, [Online]. Available: https://sid.ir/paper/1078388/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button