مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

192
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Comparison of Different Denoising Filters in Myocardial Perfusion Single Photon Emission Computed Tomography (SPECT) Images

Pages

  624-631

Abstract

 Background: Single photon emission computed tomography (SPECT) imaging is widely implemented in Nuclear Medicine for detecting coronary artery diseases. To increase the accuracy of the diagnosis, it is necessary to improve the quality of the SPECT images that can be degraded by noise. The aim of this study was to evaluate the effectiveness of using different filters such as Butterworth, Gaussian, Wiener with kernel sizes 3×3 and 5×5, and Median Modified Wiener Filters (MMWF with kernel sizes 3×3 and 5×5 to improve the quality of myocardial perfusion SPECT images with 99mTc-MIBI. Methods: A Siemens Symbia T2 dual head SPECT/CT scanner equipped with a low-energy and high-resolution collimator (LEHR) was used for collecting data for this cross-sectional-applied study. The noise ratio (SNR), peak to noise ratio (PSNR) and contrast to noise ratio (CNR) were the indices used to asses the quality of the myocardial perfusion SPECT images of 30 patients after the filters mentioned above have been applied to the images. Findings: Wiener filter with kernel size of 5×5 4. 90 ±,0. 69 and 2. 65 ±,0. 57 were found be the highest SNR and CNR indices reSPECTively. However, it had the lowest PSNR in the range of 29. 93 ±,3. 13 (dB). In addition, the highest PSNR values were associated with the Gaussian filter as 50. 09 ±,10. 63 (dB). Conclusion: The results of this study show that the wiener filter of kernel size of 5×5 outperformed the others to improve the quality of myocardial perfusion SPECT images used in this study.

Multimedia

  • No record.
  • Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Rahimian, Abdurrahim, ETEHADTAVAKOL, MAHNAZ, & MOSLEHI, MASOUD. (2022). Comparison of Different Denoising Filters in Myocardial Perfusion Single Photon Emission Computed Tomography (SPECT) Images. JOURNAL OF ISFAHAN MEDICAL SCHOOL (I.U.M.S), 40(683 ), 624-631. SID. https://sid.ir/paper/1037510/en

    Vancouver: Copy

    Rahimian Abdurrahim, ETEHADTAVAKOL MAHNAZ, MOSLEHI MASOUD. Comparison of Different Denoising Filters in Myocardial Perfusion Single Photon Emission Computed Tomography (SPECT) Images. JOURNAL OF ISFAHAN MEDICAL SCHOOL (I.U.M.S)[Internet]. 2022;40(683 ):624-631. Available from: https://sid.ir/paper/1037510/en

    IEEE: Copy

    Abdurrahim Rahimian, MAHNAZ ETEHADTAVAKOL, and MASOUD MOSLEHI, “Comparison of Different Denoising Filters in Myocardial Perfusion Single Photon Emission Computed Tomography (SPECT) Images,” JOURNAL OF ISFAHAN MEDICAL SCHOOL (I.U.M.S), vol. 40, no. 683 , pp. 624–631, 2022, [Online]. Available: https://sid.ir/paper/1037510/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button