نویسندگان: 

TAVAKOLI M.B. | KOLGHI N. | SHAHI Z. | SHANEH Z.

اطلاعات دوره: 
  • سال: 

    2008
  • دوره: 

    6
  • شماره: 

    2
  • صفحات: 

    77-82
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    326
  • دانلود: 

    0
چکیده: 

Background: Breast is one of the main radiological sensitive organs, hence it is important to evaluate ABSORBED DOSE to this organ especially to the GLANDULAR parts. It is the aim of this study to measure mean GLANDULAR DOSE and image contrast in terms of different mammographic parameters. Materials and Methods: In this study two mammography machines located at Said-al Shohada (Giotto) and Shahid Behesti (GE) hospitals were used. According to the recommendations of ACR and MQSA, breast phantoms were constructed and used for this study. For DOSE evaluation TLD dosimetry method was used. The TLD dosimeters were of LiF type and the reader was a Solaro TLD reader. Results: To obtain a constant contrast when increasing kVp from 22 to 24, it was necessary to reduce mAs by 12 percent. The obtained relation between these two parameters is: contrast=0.2829D-0.2427. It was also found that there is a linear relationship between contrast and image quality. The relation between these two parameters is: Image quality=28.117 Contarst+20.134. Increasing kVp and hence decreasing mAs results a reduction to the GLANDULAR DOSE, especially in patients with large breast. Increasing kVp from 28 to 30 results in reduction of DOSE from 6.8mGy to 5mGy. Conclusions: It was found that there has been a linear relationship between contrast and image quality. It was also found that increasing kVp necessitate to reduce mAs for a constant contrast and hence reduction of GLANDULAR DOSE.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 326

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نشریه: 

Archives of Breast Cancer

اطلاعات دوره: 
  • سال: 

    2021
  • دوره: 

    8
  • شماره: 

    3
  • صفحات: 

    183-191
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    124
  • دانلود: 

    0
چکیده: 

Background: In this work a new method for the Mean GLANDULAR DOSE evaluation in digital breast tomosynthesis (DBT) is presented. Methods: Starting from the experimental-based dosimetric index, 2ABD, which represents the average ABSORBED breast DOSE, the mean GLANDULAR DOSE MGD2ABD was calculated using a conversion function of GLANDULARity f(G), obtained through the use of Monte Carlo simulations. Results: f(G) was computed for a 4. 5 cm thick breast: from its value MGD2ABD for different compressed breast thicknesses and GLANDULARities was obtained. The comparison between MGD2ABD estimates and the dosimetric index provided in the current dosimetry protocols, following the Dance's approach, MGD Dance, showed a good agreement (<10%) for all the analyzed breast Dance thicknesses and GLANDULARities. Conclusion: The strength of the proposed method can be considered an accurate mean GLANDULAR DOSE assessment starting from few and accessible parameters, reported in the header DICOM of each DBT exam.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 124

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 4
نویسندگان: 

مولوی علی اصغر

اطلاعات دوره: 
  • سال: 

    1390
  • دوره: 

    8
  • شماره: 

    1 (پیاپی 30)
  • صفحات: 

    65-71
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    959
  • دانلود: 

    185
چکیده: 

مقدمه: هدف، محاسبه متوسط دوز جذبی غده ای پستان در ماموگرافی با هدف – فیلتر مولیبدنیم- رودیم و محاسبه دقیق و سریع دوز برای وضعیت های مختلف است.مواد و و روشها: در این پژوهش، ابتدا طیف اشعه ایکس هدف مولیبدنیم با و بدون فیلتر رودیم برای باریکه الکترون های تک انرژی با کد MCNP محاسبه شده است. سپس با استفاده از پارامترهای Sobol-Wu یک برنامه کامپیوتری به زبان فرترن برای محاسبه متوسط دوز غده ای به زبان فرترن نوشته ایم.نتایج: تغییرات متوسط دوز جذبی غده ای برحسب ولتاژ لامپ اشعه ایکس دستگاه ماموگرام و به ازای d=5 cm، HVL=0.35 mmAl، و برای مقادیرمختلف g محاسبه شده است. همچنین نتایج مربوط به تغییرات متوسط دوز جذبی غده ای به ازای یک رونتگن تابش برحسب درصد غده ای بافت پستان برای kV=28، HVL=0.4 mmAl، و d های مختلف ارائه شده است. تغییرات متوسط دوز جذبی غده ای برحسب d برای g=%60 و در سه مقدار Kv=23, 27, 35 و HVL های متناظر نیز ارائه شده است.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 959

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 185 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
اطلاعات دوره: 
  • سال: 

    2010
  • دوره: 

    18
  • شماره: 

    SUPPLEMENT 1
  • صفحات: 

    157-157
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    232
  • دانلود: 

    0
چکیده: 

Introduction: Assessment of radiation DOSE is an important task in radiation protection dosimetry whereas ABSORBED and effective DOSE measurements directly in body organs are impossible. So Monte Carlo simulations is necessary to estimate radiation DOSE. The method of DOSE calculation, the body model and the computational code can be mentioned as three main factors that have an affect on dosimetric quantities. The aim of this study is the determination of the above factors influence on the ABSORBED DOSE and effective DOSE evaluation. For this purpose different comparisons between the mathematical and the voxel phantoms were done.Methods: ORNL modified adult phantom is the mathematical phantom which is described by Cristy and Eckerman in 1987. This phantom is utilized for calculation of the ABSORBED DOSE. The effective DOSE is calculated according to the manner which is introduced in the ICRP reported 60 and 103.Results: All of the DOSEs Evaluation have an uncertainty less than 0.5%. MCNPX code and ORNL modified adult phantom are applied for the DOSE assessment in the energy range 10-9 – 20 MeV, under AP, PA, RLAT, LLAT, ROT and ISo irradiation conditions. The results are then normalized to the unit of neutron fluence. The calculated ABSORBED DOSE was compared with ICRP74 data in 9 organs and with Bozkurt et al data in 18 organs. The effective DOSE was calculated for whole body. Then these data were compared with results of a mathematical phantom and some voxel models in different irradiation geometries.Conclusion: Although the ABSORBED DOSE results of ORNL show fewer differences with ICRP data than Bozkurt et al data, one can deduce neither complete agreement nor disparity between the ORNL data and the other two data sets. Totally 73% of the ORNL data in comparison with MIRD data and 48% of data in comparison with VIP_MAN results have difference less than 15%. Comparison of the ORNL effective DOSE with some male and female voxel phantoms (TARA, HANAKO, GSF, VIP_MAN) and an analytical model (MIRD) show that the changing of body model and computational code have few influence (less than 15%) on the effective DOSE results. But changing of wR and wT parameters have a significant effect on the results so that the largest discrepancies are about 100% on some data.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 232

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1399
  • دوره: 

    8
  • شماره: 

    2 (ویژه نامه پرتوهای غیریون ساز)
  • صفحات: 

    13-16
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    552
  • دانلود: 

    111
چکیده: 

آسیب حاصل از تابش به میران جذب انرژی بستگی دارد، و تقریباً با تراکم انرژی جذب شده در بافت متناسب است. در بررسی تابش خارجی با شار انرژی معین، مقدار دز جذب شده در هر نقطه از بافت به نوع تابش، انرژی تابش، فاصله عمق محل دریافت دز و اجزای اصلی سازنده محیط جاذب در آن نقطه بستگی دارد. در پرتو درمانی، میزان دز جذبی یا انرژی جذب شده در بافت حائز اهمیت است. این مسئله در خصوص پرتوهای یونساز همانند ایکس و گاما تقریباً شناخته شده است و در پروتکل های درمانی اجرا می گردد. لیکن در لیزر درمانی کمتر به آن توجه شده است. به علت وجود خطرات بالفعل در کار با لیزر، دزیمتری در لیزر درمانی بسیار حائز اهمیت است و علاوه بر رعایت حدود مجاز تابشی به لحاظ حفاظت پرتویی لزوماً میزان دز تابش جهت دستیابی به اثر مطلوب از الزامات این کاربرد لیزر در پزشکی است.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 552

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 111 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نویسندگان: 

نشریه: 

PHYSICA MEDICA

اطلاعات دوره: 
  • سال: 

    2018
  • دوره: 

    51
  • شماره: 

    -
  • صفحات: 

    38-47
تعامل: 
  • استنادات: 

    1
  • بازدید: 

    68
  • دانلود: 

    0
کلیدواژه: 
چکیده: 

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 68

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
اطلاعات دوره: 
  • سال: 

    1398
  • دوره: 

    8
  • شماره: 

    4 (ویژه نامه پرتوهای یون ساز)
  • صفحات: 

    155-162
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    556
  • دانلود: 

    108
چکیده: 

با توجه به کاربرد فراوان آزمون های رایج ماموگرافی به منظور غربالگری و تشخیص سرطان پستان، نگرانی هایی در مورد افزایش دوز جذبی بیمار، به علت حساس بودن بافت سینه و دوز جذبی در بافت پستان، وجود دارد. بنابراین اطلاع از میزان دوز متوسط غده ای قبل از پرتودهی به بیمار از طریق تخمین آن می تواند، کمک کننده باشد. بدین منظور و برای اندازه گیری داده ها از فانتومی با مشخصات مشابه محتویات بافت سینه استفاده شده و میزان کرمای هوا در سطح ورودی به پوست، ماکزیمم کیلو ولتاژ، میلی آمپر ثانیه، ضخامت لایه نیم جذب و نوع فیلتر/هدف، ثبت گردید. سپس مدل شبکه عصبی پرسپترون چند لایه با الگوریتم آموزشی لونبرگ-مارکوارت، با استفاده از نرم افزار متلب آموزش داده شده و کرمای هوای سطحی، تخمین زده شد. برای رسیدن به بهترین نتیجه، شبکه عصبی با پارامترهای متفاوت از جمله گرادیان خطا و تعداد نورون های لایه پنهان و روش آموزش مناسب بهینه شد. پس از اجرای برنامه برای تعداد نورون های متفاوت، مشخص شد که تعداد 35 نورون، بهینه ترین مقدار می باشد که ضریب رگرسیون 95. 7 درصد را به دست داده و مقدار میانگین مربعات خطا برای تمام داده ها، 0. 437 میلی گری است که 4. 8 درصد دامنه تغییرات خروجی می باشد و مبین پیش گویی با صحت 95. 2 درصدی در پژوهش حاضر می باشد. روش پیشنهادی در تحقیق حاضر با استفاده از شبکه های عصبی در پیش بینی کرمای هوا، تخمین کرمای هوای احتمالی بیمار را قبل از اینکه در معرض اشعه ایکس قرار بگیرد، میسر می کند. نتایج نشان داده است که ضریب رگرسیون بدست آمده، مبین اختلاف 4. 3 درصدی بین کرمای اندازه گیری شده توسط دوزیمتر حالت جامد در میدان پرتو و مقدار پیش گویی شده در پژوهش حاضر می باشد که در مقایسه با روش شبیه سازی مونت کارلو از صحت خوبی نیز برخوردار است.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 556

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 108 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نویسندگان: 

مولوی علی اصغر

اطلاعات دوره: 
  • سال: 

    1386
  • دوره: 

    65
  • شماره: 

    3
  • صفحات: 

    13-16
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    800
  • دانلود: 

    142
چکیده: 

زمینه و هدف: نوشتن یک کد کامپیوتری برای محاسبه متوسط دوز جذبی غده ای در ماموگرافی برای تخمین دوز دقیق و سریع، موثر است.روش بررسی: در این پژوهش، با استفاده از پارامترهای محاسبه شده توسط Sobol-Wu، یک کد برای محاسبه دوز به زبان فرترن نوشته شده است. این کد کامپیوتری، دوز را برای ماموگرامهای با هدف- فیلتر Rh-Rh, Mo-Mo و Mo-Rh به ازای پارامترهای ورودی: ولتاژ، ضخامت نیم لایه اشعه X، ضخامت پستان، و کسر غده ای بافت پستان محاسبه می کند.یافته ها: با اجرای کد، تغییرات متوسط دوز جذبی غده ای برای سه آرایش هدف- فیلتر و به ازای HVL=0.34 mm, d=4 cm، و g=0.5 بر حسب ولتاژ لامپ اشعه X دستگاه ماموگرام، و تغییرات آن بر حسب درصد غده ای بافت پستان به ازای HVL=0.34 mm, kV=25، و d=4 cm محاسبه شده است. همچنین تغییرات متوسط دوز جذبی غده ای بر حسب HVL اشعه X دستگاه ماموگرام به ازای d=4, kV=28، و g=0.6 گزارش شده و نتایج بدست آمده از این کد در توافق بسیار خوبی با نتایج دیگران است.نتیجه گیری: علاوه بر جامعیت، سرعت و قدرت دوز محاسبه شده و استفاده آسان کد توسط کاربر، می توان از آن برای بهینه سازی دوز تابشی در ماموگرافی استفاده کرد.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 800

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 142 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1385
  • دوره: 

    9
  • شماره: 

    3 (پیاپی 31)
  • صفحات: 

    210-215
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    1650
  • دانلود: 

    0
چکیده: 

هدف: تشعشعات کیهانی از فضای خارج به طور مستمر به سطح زمین می تابد. میزان پرتوگیری محیطی در آتمسفر زمین، به جز از فعالیتهای غیر معمول و گذرای خورشیدی، اغلب تابعی از عرض جغرافیایی و ارتفاع از سطح زمین است. این پرتوگیری در عرض جغرافیایی معتدل شمالی و در ارتفاع هواپیماها به میزان 20-25 برابر افزایش می یابد. بنابراین کادر پروازی و مسافرانی که به طور مکرر در پروازند به میزان زیادی در معرض این تابشهای کیهانی قراردارند. در این مقاله به جنبه های عمومی حفاظت پرتوی برای کادر پروازی که در پروازهای داخل کشور در معرض اشعه کیهانی قراردارند، توجه شده است.مواد و روش کار: میزان دوز محیطی در چندین پرواز داخلی با استفاده از سرویمتر مدل RDS-110 اندازه گیری شده است. بر مبنای اطلاعات اندازه گیری شده و مدت پرواز، دوز موثر کادر پروازی ابتدا محاسبه و سپس با نتایج  به دست آمده از نرم افزار CARI-6 که توسط انستیتو هوا - فضای شهری در شهر اکلاهمای امریکا معرفی شده، مقایسه گردیده است. به علت تطابق بسیار خوب مقادیر اندازه گیری با نتایج محاسبات، از برنامه مذکور برای تعیین میزان دوز در سایر ارتفاعات و در سراسر کشور استفاده شده و الگوریتم ساده ای برای محاسبه دوز مسیرهای مختلف در پروازهای داخلی ارایه گردیده است.نتایج: نتایج اندازه گیری ها نشان می دهد که میزان معادل دوز در ارتفاعات مربوط به پروازهای داخلی می تواند از رابطه a(h)b  محاسبه شود. در این رابطه h ارتفاع پرواز برحسب هزار پا، a و b ثابتهایی هستند که به محل جغرافیایی بستگی دارند. با استفاده از میزان معادل دوز و پرفایل پرواز، الگوریتم ساده ای برای برآورد دوز مسیر در پروازهای داخلی ارایه شده است.نتیجه گیری: حدود دوز سالانه عموم افراد جامعه به کادر پروازی این اجازه را می دهد که سالانه 290 ساعت پرواز در ارتفاعات 27-33 هزارپا را در پروازهای داخلی داشته باشند، و کارکنان زن در کادر پروازی در زمان حاملگی تنها می بایستی از پرتوگیری خود مطلع باشند.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 1650

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1387
  • دوره: 

    7
  • شماره: 

    2 (مسلسل 57)
  • صفحات: 

    254-262
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    1360
  • دانلود: 

    352
چکیده: 

هدف: پرتودرمانی یکی از راههای درمان سرطان است که در آن با تابش پرتوهای یونیزان به سلولهای تومورال، از تکثیر و رشد سلولها جلوگیری کرده و آنها را از بین می برند. هر چه میزان انرژی واگذار شده توسط پرتو یونیزان به ناحیه تحت درمان (دوز جذبی) بیشتر باشد، سلولهای تومورال بیشتری کشته می شوند. در این تحقیق به بررسی تاثیر دما بر دوز جذبی ناشی از پرتوتابی پرداخته ایم. هدف اصلی در پرتودرمانی، رسیدن دوز مناسب به صورت همگن به بافت تومورال و حفاظت بافتهای سالم اطراف تومور است.روش بررسی: دوز جذبی را در فانتوم آب با ابعاد 30´30´30 cm برای میدانهای با ابعاد (از 5´5 cm تا 20´20) تحت تابش گامای حاصل از چشمه کبالت 60 و در عمقهای 5 تا 9 سانتیمتر برای دماهای 30oC تا 50oC بوسیله اتاقک یونیزاسیون فارمر و الکترومتر همراهش اندازه گیری کردیم. سپس منحنی تغییرات دوز جذبی بر حسب دما را برای هر آزمایش رسم نمودیم و در ادامه با معرفی کمیت TER، درصد افزایش دوز در اثر تغییر دما را محاسبه و نمودار تغییرات آن را نیز رسم نمودیم.یافته ها: نمودارها و جداول نشان می دهند که، دوز جذبی و در نتیجه TER، در فانتوم آب، در هر عمق و هر میدانی با افزایش دما، زیاد می شود که این افزایش از دمای تقریبا 42oC به بالا تشدید می شود.نتیجه گیری: این مطالعه نشان می دهد که روش دمافزایی تغییرات ناگهانی در ساختار آب رخ و باعث افزایش دوز جذبی می شود.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 1360

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 352 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
litScript
telegram sharing button
whatsapp sharing button
linkedin sharing button
twitter sharing button
email sharing button
email sharing button
email sharing button
sharethis sharing button