مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

460
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

377
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

CLAY REINFORCEMENT USING GEOGRID EMBEDDED IN THIN LAYERS OF SAND

Pages

  224-235

Abstract

 Large size DIRECT SHEAR TESTs (i.e.300 x 300mm) were conducted to investigate the INTERACTION between CLAY reinforced with GEOGRIDs embedded in thin layers of SAND. Test results for the CLAY, SAND, CLAY-sand, CLAY-GEOGRID, SANDGEOGRID and CLAY-sand-GEOGRID are discussed. Thin layers of SAND including 4, 6, 8, 10, 12 and 14mm were used to increase the INTERACTION between the CLAY and the GEOGRIDs. Effects of SAND layer thickness, normal pressure and transverse GEOGRID members were studied. All tests were conducted on saturated CLAY under unconsolidated-undrained (UU) conditions. Test results indicate that provision of thin layers of high strength SAND on both sides of the GEOGRID is very effective in improving the strength and deformation behaviour of reinforced CLAY under UU loading conditions. Using GEOGRIDs embedded in thin layers of SAND not only can improve performance of CLAY backfills but also it can provide drainage paths preventing pore water pressure generations. For the soil, GEOGRID and the normal pressures used, an optimum SAND layer thickness of 10mm was determined which proved to be independent of the magnitude of the normal pressure used. Effect of SAND layers combined with the GEOGRID REINFORCEMENT increased with increase in normal pressures. The improvement was more pronounced at higher normal pressures. Total shear resistance provided by the GEOGRIDs with transverse members removed was approximately 10% lower than shear resistance of GEOGRIDs with transverse members.

Multimedia

  • No record.
  • Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    ABDI, M.R., SADRNEZHAD, S.A., & ARJMAND, M.A.. (2009). CLAY REINFORCEMENT USING GEOGRID EMBEDDED IN THIN LAYERS OF SAND. INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 7(4), 224-235. SID. https://sid.ir/paper/271819/en

    Vancouver: Copy

    ABDI M.R., SADRNEZHAD S.A., ARJMAND M.A.. CLAY REINFORCEMENT USING GEOGRID EMBEDDED IN THIN LAYERS OF SAND. INTERNATIONAL JOURNAL OF CIVIL ENGINEERING[Internet]. 2009;7(4):224-235. Available from: https://sid.ir/paper/271819/en

    IEEE: Copy

    M.R. ABDI, S.A. SADRNEZHAD, and M.A. ARJMAND, “CLAY REINFORCEMENT USING GEOGRID EMBEDDED IN THIN LAYERS OF SAND,” INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, vol. 7, no. 4, pp. 224–235, 2009, [Online]. Available: https://sid.ir/paper/271819/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button