مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

165
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Evaluation of dosimetry quantities in passive scattering and spot scanning methods in proton therapy based on GATE simulation

Pages

  34-42

Abstract

 The spot-scan based methods are expected to perform better than other methods for Proton therapy in delivering the dose to the intended target. In this study, the GATE computer code is used to evaluate important dosimetric quantities in Proton therapy, such as Full width at half maximum, peak position, range and peak-to-entrance dose ratio (percentage depth dose) in the Proton therapy process under the same conditions based on Spot scanning and Passive scattering. Water phantom was selected and system energy parameters were measured using a set of depth-dose curve in the energy range of 120 to 235 MeV. Bragg peaks were generated with an accuracy of 0. 7 mm in range. Spread out Bragg-peak were produced with 7 cm modulation and 10 mm range accuracy and peak-to-entrance dose ratio difference at an input dose of 8%. To evaluate the versatility of the beam, the Full width at half-maximum was evaluated with a maximum difference of 7% between the two methods. As a result, based on the simulations performed for different beam delivery systems, the ability of the Spot scanning method in adapting to the target volume, better control over dose distribution and less extra-tumor dose was demonstrated.

Multimedia

  • No record.
  • Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    ASADI, A., HOSSEINI, S.A., & VOSOUGHI, N.. (2022). Evaluation of dosimetry quantities in passive scattering and spot scanning methods in proton therapy based on GATE simulation. JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 43(2 (100) ), 34-42. SID. https://sid.ir/paper/1032412/en

    Vancouver: Copy

    ASADI A., HOSSEINI S.A., VOSOUGHI N.. Evaluation of dosimetry quantities in passive scattering and spot scanning methods in proton therapy based on GATE simulation. JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY[Internet]. 2022;43(2 (100) ):34-42. Available from: https://sid.ir/paper/1032412/en

    IEEE: Copy

    A. ASADI, S.A. HOSSEINI, and N. VOSOUGHI, “Evaluation of dosimetry quantities in passive scattering and spot scanning methods in proton therapy based on GATE simulation,” JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, vol. 43, no. 2 (100) , pp. 34–42, 2022, [Online]. Available: https://sid.ir/paper/1032412/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button