THE EFFECTS OF PRE-IONIZER CATHODE AND ANODE DIMENSION ON THE MAIN ELECTRICAL DISCHARGE REGION IN THE TEA CO2 LASER

Type: PAPER
Author(s): BAHRAMPOUR ALIREZA,A.GANJOVI ALIREZA
 
 
 
Name of Seminar: IRAN PHYSICS CONFERENCE
Type of Seminar:  CONFERENCE
Sponsor:  PHYSICS SOCIETY OF IRAN
Date:  2005Volume -
 
 
Abstract: 

IN THIS PAPER, BY THE USE OF THE ELECTRICAL MODEL, WE HAVE STUDIED THE EFFECTS OF THE PRE-IONIZER CATHODE AND ANODE DIMENSION ON THE MAIN DISCHARGE REGION OF THE CO2 LASER. WE HAVE STUDIED THESE EFFECTS BY MEASURING UV ENERGY THAT IS PRODUCED IN THE CORONA PRE-IONIZATION, ENTERING TO THE MAIN DISCHARGE REGION. WE HAVE ALSO SHOWN THAT THE UV RADIATION IN THE MAIN DISCHARGE REGION OF THE LASER HAS A MAXIMUM VALUE ACCORDING TO THE DIMENSIONS OF PRE-IONIZER CATHODE WHICH IT IS IN GOOD AGREEMENT WITH THE EXPERIMENTAL RESULTS.

 