Click for new scientific resources and news about Corona[COVID-19]

Paper Information

Journal:   AMIRKABIR   Summer 2003 , Volume 14 , Number 55-E; Page(s) 962 To 970.
 
Paper: 

ANALYTICAL AND EXPERIMENTAL INVESTIGATION ON FAILURE OF MASONRIES UNDER SHEAR LOADING

 
 
Author(s):  ABD ELAHI ALI BEYK JAMAL*
 
* DEPARTMENT OF IRRIGATION ENGINEERING,FACULTY OF AGRICULTURE, TEHRAN UNIVERSITY
 
Abstract: 

Ultimate shear strength in earthquake resistant masonry walls has especial importance. Horizontal loading in masonry walls (parallel to the Joints) causes horizontal shear failure between mortar and brick or diagonal tension failure. In masonry shear connection naturally is independent of mortar strength but perforated bricks because of mechanical shear keys with mortar cause increase in shear strength (at least in case of low vertical pressure on masonry). Masonry strength against horizontal shear failure would increase directly with vertical loading on brick and mortar. So in the case of high vertical pressure failure is due to diagonal tension and above the key effects they are not very significant.

 
Keyword(s):  MASONRY WALL ,SHEAR CONNECTION FAILURE , DIAGONAL TENSION ,SHEAR STRENGTH ,JOINT, SHEAR KEY, SHEAR STRESS, REINFORCING ,LATERAL LOADING
 
References: 
  • ندارد
 
  Persian Abstract Yearly Visit 70
 