Paper Information

Journal:   JOURNAL OF FACULTY OF ENGINEERING (UNIVERSITY OF TABRIZ)   SUMMER 2006 , Volume 33 , Number 1 (43) ELECTRICAL ENGINEERING; Page(s) 61 To 70.
 
Paper: 

ANALYSIS OF VOLTAGE TOLERANCE OF INDUCTION MOTORS FED FROM PWM VOLTAGE SOURCE INVERTER FOR BALANCED AND UNBALANCED SAGS

 
 
Author(s):  MOHAMMADI SALAH*
 
* SCHOOL OF ELECTRICAL ENGINEERING, SHARIF UNIVERSITY OF TECHNOLOGY
 
Abstract: 

Induction motors are the type of equipment most sensitive to voltage changes. In this paper behavior of induction motor fed from voltage source inverter under balanced and unbalanced voltage sags has been analyzed. Effects of various faults on the DC bus for six and twelve pulse rectifiers and induction motor have been analyzed. Voltage tolerance curves of induction motor for various rating capacitor and for various fault due to amount of allowable slip changes have been obtained. Keeping the drive online would be the best way of mitigating the effect of sag on the mechanical load. Since 66% of the faults are related to single-phase and phase-to-phase, by adding relatively amount of DC bus capacitance, these faults for drives can be tolerated.

 
Keyword(s): INDUCTION MOTORS, PWM VOLTAGE SOURCE INVERTER, VOLTAGE SAGS, BALANCED AND UNBALANCED FAULTS
 