Click for new scientific resources and news about Corona[COVID-19]

Paper Information

Journal:   IRANIAN JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING (IJECE)   SUMMER-FALL 2007 , Volume 6 , Number 2; Page(s) 125 To 128.
 
Paper: 

CURRENT ZERO HARMONIC COMPONENT AND MIN/MAX VALUES BASED STRATEGY FOR ONE AND SIMULTANEOUS TWO OPEN-SWITCHES FAULT AUTOMATIC DIAGNOSTIC AND LOCATION IN TWO LEVEL THREE PHASE VOLTAGE INVERTER

 
 
Author(s):  BENSLIMANE T.*
 
* UNIVERSITY OF BOUMERDES, ALGERIA
 
Abstract: 

The good knowledge and information about the fault mode behavior of the PWM voltage source inverter is important to improve system design, protection and fault tolerant control. This paper develops a real-time condition-monitoring algorithm for 3-phase pulse width modulation (PWM) inverter. It is designed to detect and identify the transistor open-circuit fault and simultaneous two transistors open-circuit fault, which commonly occurs in the inverter drive system. The condition monitoring mechanism is based on phases currents mean, maximum and minimum values as fault indicators. The developed system has been rigorously assessed theoretically and it has been shown that the system is robust and reliable. Simulation results are presented.

 
Keyword(s): ALTERNATIVE CURRENT, BOOLEAN VALUE, FAULT DIAGNOSIS, IGBT, LOGIC FUNCTIONS, MIN AND MAX VALUE, TWO LEVEL THREE PHASE VOLTAGE INVERTER, ZERO HARMONIC COMPONENT
 
References: 
  • ندارد
 
  pdf-File tarjomyar Yearly Visit 67
 