Thermodynamic And Economic Optimization Of The Refrigeration System In A Building

 
 
Author(s):  Sadeghi A., Davoud Abadi Farahani S.*
 
* D‌e‌p‌t. o‌f M‌e‌c‌h‌a‌n‌i‌c‌a‌l E‌n‌g‌i‌n‌e‌e‌r‌i‌n‌g, A‌r‌a‌k U‌n‌i‌v‌e‌r‌s‌i‌t‌y o‌f T‌e‌c‌h‌n‌o‌l‌o‌g‌y
 
Abstract: 
An air conditioning system for a sample building with an area of 97. 1m2 on the floor was considered. Three cooling systems are considered: a normal compression refrigeration system, a refrigeration system with an economizer, a refrigeration system with two compressors. The working fluid in three systems is R-134 a. First, thermodynamic and economic modeling of each cycle was done, which was followed by considering the performance coefficient as thermodynamic representative and the total income requirement as economic representative. The functional pressures and the ratio of mass flow rate in the economizer are chosen as decision variables. The optimization method is Multi objective Genetic algorithm (NSGAII), and the final option is chosen using the Analytic Hierarchy Process. The economic model takes into account the cost of the components, including amortization and maintenance. In order to deu{fb01}ne a cost function, which depends on the optimization parameters of interest, component costs have to be expressed as functions of thermodynamic variables. The noteworthy point is that the cycle costs are higher than the other two cycles, and the compressor cycle costs are higher than the normal refrigeration cycle. This behavior results from the higher heating of the cycle with two compressors compared to the normal cycle. The cost of the installation of an economizer has increased the cost of the refrigeration cycle with an economizer. In this cycle, the flow rate in the evaporator is low and, to achieve the chiller load, the heat exchanger surface is higher. The cycle performance with an economizer is more than that in two other cycles, and the cost of the cycle with two compressors is higher than that of the other two cycles. In the evaluation of options, the scale of the performance coefficient is measured by 2 to 1. Based on the observed results, the normal compression refrigeration system is chosen because it is more inexpensive than other options; then, the system with an economizer is chosen as the second option.
 
Keyword(s): multi-objective optimization,thermodynamic and economic modeling,choice,refrigeration cycle
 
 
International related papers: 
  • No item.
 
Most related Highly related Moderately related Least related
 
References: 
  • Not Registered.
  •  
  •  
 
Citations: 
  • Not Registered.
 
+ Click to Cite.
APA: Copy

SADEGHI, A., & DAVOUD ABADI FARAHANI, S. (2019). THERMODYNAMIC AND ECONOMIC OPTIMIZATION OF THE REFRIGERATION SYSTEM IN A BUILDING. MECHANICAL ENGINEERING SHARIF (SHARIF: MECHANICAL ENGINEERING), 35-3(2 ), 107-116. https://www.sid.ir/en/journal/ViewPaper.aspx?id=822935



Vancouver: Copy

SADEGHI A., DAVOUD ABADI FARAHANI S.. THERMODYNAMIC AND ECONOMIC OPTIMIZATION OF THE REFRIGERATION SYSTEM IN A BUILDING. MECHANICAL ENGINEERING SHARIF (SHARIF: MECHANICAL ENGINEERING). 2019 [cited 2022May18];35-3(2 ):107-116. Available from: https://www.sid.ir/en/journal/ViewPaper.aspx?id=822935



IEEE: Copy

SADEGHI, A., DAVOUD ABADI FARAHANI, S., 2019. THERMODYNAMIC AND ECONOMIC OPTIMIZATION OF THE REFRIGERATION SYSTEM IN A BUILDING. MECHANICAL ENGINEERING SHARIF (SHARIF: MECHANICAL ENGINEERING), [online] 35-3(2 ), pp.107-116. Available: https://www.sid.ir/en/journal/ViewPaper.aspx?id=822935.



 
 
Persian Abstract Yearly Visit 42
 
 
Latest on Blog
Enter SID Blog