Click for new scientific resources and news about Corona[COVID-19]

Paper Information

Journal:   PAJOUHESH DAR PEZESHKI   2019 , Volume 43 , Number 3 ; Page(s) 150 To 156.
 
Paper: 

Homogeneous Phantom Equivalent Chest For Examination Of Image Quality Testing In Pediatric Chest X-Ray

 
 
Author(s):  Rahmani Fereshte, Deevband Mohammadreza*, Kaveh Zeinab, Mohsenzadeh Behzad, Azimi Leila, Pirayesh Elahe
 
* Shahid Beheshti University of Medical Sciences, Faculty of Medicine, Department of Physics and Biomedical Engineering
 
Abstract: 
Background: The pediatrics' chest X-rays using digital radiography are considered important because of the high rates of this test as well as the increased sensitivity of children to ionizing radiation compared with adults. Therefore, clarification of radiographic methods that reduce the dose and maintain or even increase the quality of the image is of great importance and thus of interest to researchers. The goal of the present study was to build a chest equivalent homogeneous phantom to evaluate the image quality in radiographic tests in four age groups of children based on the ICRP103 age category classification. Materials and Methods: The X-ray spectrum approved by IPEM was used as the input x-ray source in the Monte Carlo code. The geometric phantom equivalent to the ORNL body was then simulated to calculate the absorb dose using Monte Carlo code. The results of the simulation were used to construct equivalent chest phantom for children. Results: In order to validate and verify the performance of the equivalent phantoms simulated for each age group, the attenuation and dispersion of the phantom at the field were measured. For this purpose, the percentages of the depth dose in the simulation conditions was compared with those of the experimental results, which can be used to examine the attenuation in different layers. The calculated error was less than 5% on the depth dose for the Monte Carlo and the experimental space and it indicates Confirmation of simulated program. After simulation, the phantom was made in similar dimensions with different thicknesses of the Plexiglas pediatrics age ranges. Conclusion: It seems that the phantom designed in the current study can be used to assess the doses of children in different age groups. It can also be used with local fitting for image quality control tools, such as contrast, resolution, etc, for evaluating the parameters related to the quality of the image in the actual condition.
 
Keyword(s): Monte Carlo,Geometric Phantom Equivalent Body,Chest Phantom,Pediatric Radiography
 
 
International related papers: 
  • No item.
 
Most related Highly related Moderately related Least related
 
References: 
  • Not Registered.
  •  
  •  
 
Citations: 
  • Not Registered.
 
+ Click to Cite.
APA: Copy

Rahmani, F., & Deevband, M., & Kaveh, Z., & Mohsenzadeh, B., & AZIMI, L., & PIRAYESH, E. (2019). Homogeneous Phantom Equivalent Chest for Examination of Image Quality Testing in Pediatric Chest X-Ray. PAJOUHESH DAR PEZESHKI, 43(3 ), 150-156. https://www.sid.ir/en/journal/ViewPaper.aspx?id=793294



Vancouver: Copy

Rahmani Fereshte, Deevband Mohammadreza, Kaveh Zeinab, Mohsenzadeh Behzad, AZIMI LEILA, PIRAYESH ELAHE. Homogeneous Phantom Equivalent Chest for Examination of Image Quality Testing in Pediatric Chest X-Ray. PAJOUHESH DAR PEZESHKI. 2019 [cited 2022January23];43(3 ):150-156. Available from: https://www.sid.ir/en/journal/ViewPaper.aspx?id=793294



IEEE: Copy

Rahmani, F., Deevband, M., Kaveh, Z., Mohsenzadeh, B., AZIMI, L., PIRAYESH, E., 2019. Homogeneous Phantom Equivalent Chest for Examination of Image Quality Testing in Pediatric Chest X-Ray. PAJOUHESH DAR PEZESHKI, [online] 43(3 ), pp.150-156. Available: https://www.sid.ir/en/journal/ViewPaper.aspx?id=793294.



 
 
Persian Abstract Yearly Visit 52
 
 
Latest on Blog